Summary Table of Blast Hazard Mitigation Test Results* |
||||
GSA |
Pressure, Implulse |
Window Type |
Glass Strength |
Film and Attachment |
1 |
4 psi, 28 psi-mec |
dual |
TTG† |
8 mil with Wetglaze |
dual |
TTG |
8 mil with FrameLok |
||
2 |
4 psi, 28 psi-mec |
single |
TTG |
8 mil with FrameLok
|
2 |
4 psi, 28 psi-mec |
dual |
ANN†† |
8 mil with Wetglaze |
dual |
ANN |
8 mil with FrameLok
|
||
3b |
4 psi, 28 psi-mec |
single |
ANN |
7 mil with no attachement |
single |
ANN & TTG |
8 mil with Wetglaze |
||
single |
ANN |
8 mil with FrameLok
|
||
single |
ANN |
8 mil with Elite
|
||
single |
ANN & TTG |
8 mil with Gullwing™**
|
||
3b |
6 psi, 42 psi-mec |
single |
ANN |
8 mil with no attachment
|
ANN |
8 mil with Wetglaze |
|||
3b |
10 psi, 50 psi-mec |
dual |
ANN |
15 mil with Wetglaze |
3b |
12.8 psi, 68 psi-mec |
dual |
ANN |
8 mil with Gullwing™ |
*Newest test results indicated in bold; †TTG = Tempered Glass; ††ANN = Annealed glass **Gullwing™ is a trademark of FrameGard Inc. |
||||
Summary Table of Hurricane Tests |
|||||||
Film |
Glass |
Frame & Attachment |
Air Infiltration Test |
Water Infiltration Test | Uniform Static Load Test | Impact Test | Cyclic Load Test |
LLumar 6 mil |
3/16" Tempered | Aluminum, Wet Glaze | ASTM E283 & TAS 202 | ASTM E331 & TAS 202 | ASTM E330 & TAS 202 | TAS-201 Small Missile | TAS-203 |
LLumar 8 mil |
3/16" Tempered | Aluminum, Wet Glaze | ASTM E283 & TAS 202 | ASTM E331 & TAS 202 | ASTM E330 & TAS 202 | TAS-201 Small Missile | TAS-203 |
LLumar 8 mil |
1/4" Annealed | Aluminum, Wet Glaze | ASTM E283 | ASTM E331 | ASTM E330 | ASTM E1886/1996 "C" Large Missile | ASTM E1996 |
LLumar 8 mil Solar |
3/16" Tempered | Aluminum, Wet Glaze | ASTM E283 | ASTM E331 | ASTM E330 | ASTM E1886/1996 "A" Small Missile | ASTM E1996 |
LLumar 8 mil Solar |
1/4" Annealed | Aluminum, Wet Glaze | ASTM E283 | ASTM E331 | ASTM E330 | ASTM E1886/1996 "C" Large Missile | ASTM E1996 |
VISTA 8 mil Solar |
1/4" Annealed | Aluminum, Wet Glaze | ASTM E283 | ASTM E331 | ASTM E330 | ASTM E1886/1996 "C" Large Missile | ASTM E1996 |
LLumar 8 mil* (Fortified Window) |
1/4" Annealed | Aluminum, Wet Glaze | ASTM E283 | ASTM E331 | ASTM E330 | ASTM E1886/1996 "D" Large Missile | ASTM E1996 |
LLumar 11 mil |
1/4" Tempered | Aluminum, Wet Glaze | ASTM E283 | ASTM E331 | ASTM E330 | ASTM E1886/1996 "C" Large Missile | ASTM E1996 |
LLumar 8 mil |
1/4" Tempered Dual Pane | Aluminum, Wet Glaze | ASTM E283 | ASTM E331 | ASTM E330 | ASTM E1886/1996 "C" Large Missile | ASTM E1996 |
Failure Citeria: Air Infiltration Test: No Air leakage as specified by standard Water Infiltration Test: No Water leakage as specified by standard Uniform Static Load Test: No glass breakage or glazing failure at specified design pressure Impact Test: Large missile: no penetration or glazing failure Cyclic Load Test: No glazing failure |
|||||||